Кошик

0 Товар(а) - 0.00 USD
До кошика

Пошук по каталогу

Осциллограф HANTEK DSO5102P 100МГц, 1ГС/с (Код: )

Хіти: 40 | Рейтинг:
Осциллограф HANTEK DSO5102P 100МГц, 1ГС/с
zoom Збільшити зображення

Лінк на офіційну сторінку виробника: http://hantek.com/en/ProductDetail_3_26.html

Лінк на інструкцію: http://www.hantek.ru/products/mans/DSO5000B_manual_rus.pdf


Sample Rate    Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/s
Acquisition Modes    
Normal    Normal data only
Peak Detect    High-frequency and randon glith capture
Average    Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling    AC, DC, GND
Inpits Impendance    1MΩ±2% ‖20pF±3pF
Probe Attenuation    1X, 10X
Supported Probe Attenuation Factor    1X, 10X, 100X, 1000X
Maximum Input Voltage    CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range    500MS/s--1GS/s
Waveform Interpolation    (sin x)/x
Record Length    40K
SEC/DIV Range    2ns/div to 80s/div
Sample Rate and
Delay Time Accuracy    ±50ppm(at over any ≥1ms time interval)
Offset Range        20ns/div to 80us/div; (-8div x s/div) to 40ms;
Delta Time Measurement Accuracy 
(Full Bandwidth)    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution    8-bit resolution, all channel sampled simultaneously
Position Range    2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V
Bandwidth        100MHz    
Rise Time at BNC( typical)         3.5ns    
Math    +, -, *, /, FFT
FFT    Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit    20MHz
Low Frequency Response (-3db)    ≤10Hz at BNC
DC Gain Accuracy    ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
Average Acquisition Mode    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability, 
Average Acquisition Mode    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types    Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source    CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes    Auto, Normal, Single
Coupling Type    DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)    DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):       
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz; 
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range    CH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)    Operates with input signals ≥50Hz
Video Trigger    
Video Trigger Type     CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type    Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range    100ns ~ 10s
Pulse Width Trigger    
Pulse Width Trigger Mode    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range    20ns ~ 10s
Slope Trigger    
Slope Trigger Mode    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range    20ns ~ 10s
Overtime Trigger    
Over Time Mode    Rising edge or Falling edge
Time Range    20ns ~ 10s
Alternative Trigger    
Trigger on CH1    Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2    Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter    
Readout Resolution    6 digits
Accuracy (typical)    ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range    AC coupled, from 4Hz minimum to rated bandwidth
Signal Source    Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement    Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Auto Measuerment    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type    7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution    800 horizontal by 480 vertical pixels
Display Contrast    Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)    About 5Vpp into ≥1MΩ load
Frequency(typical)    1kHz
Power Supply
Supply Voltage    100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption    <30W
Fuse    2A, T rating, 250V
Environmental
Temperature    Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling Method    Convection
Humidity    +104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
Altitude    Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size    Length 385mm, Width 200mm, Height 245mm
Weight    3.5KG(with Packing);  2.08KG(without Packing)

Ціна: 250.00 USD
плюс доставка
Кількість: 
Відгук

Коломия
Івано-Франківська 78200
Україна

+380(67) 290-4416
+380(50) 597-9614

avl-goverla